Blood glucose, tissue glucose and HbA1c show glucose levels at different measurement sites and over different periods of time. A blood measurement shows how much glucose (sugar) is in the blood at the time of measurement. A continuous glucose monitoring (CGM) sensor records glucose in the subcutaneous tissue and shows how it changes over time. The HbA1c value gives an indication of how high glucose exposure has been over the past weeks.

The values complement one another, but they are not directly interchangeable. To interpret them, it is important to know where the measurement was taken, what period the value refers to and under what conditions the measurement was made.

Blood glucose shows a single point in time

“Blood sugar” is the common term for glucose in the blood. A fingertip measurement or a laboratory test shows how high the glucose concentration was at the time of measurement.

The value changes over the course of the day. Food, exercise, stress and illness can all affect blood glucose. A measurement can therefore only be assessed together with its timing and the reason it was taken. A single value shows neither the whole course of the day nor longer-term fluctuations.

The type of measurement matters too: a fingerstick reading from a self-monitoring device is not the same as a standardized laboratory value. For a diabetes diagnosis, laboratory values are assessed against defined criteria. A single abnormal reading is not always enough for a diagnosis.

Tissue glucose makes the trend visible

A CGM sensor sits under the skin and measures glucose in the interstitial fluid, the fluid between the cells. This means it does not directly measure glucose in the blood. The continuous readings show which direction glucose is moving and how it changes over the course of the day.

Blood glucose and tissue glucose are closely related, but they do not always match exactly. When glucose rises or falls quickly, the sensor often shows the change in the blood only after a delay. There is no fixed delay that applies to all devices and situations.

That is why the trend is often more useful than a single sensor value. Trend arrows and the readings before and after provide additional context. If the display does not match how you feel, follow the instructions for your device. Depending on the situation, a blood measurement can help verify the value.

HbA1c summarizes glucose exposure over recent weeks

The HbA1c value is determined in a laboratory from a blood sample. It shows what proportion of hemoglobin, the red blood pigment, has glucose bound to it. Because red blood cells stay in the body for a longer time, HbA1c reflects glucose exposure over the past weeks, roughly two to three months. The most recent weeks influence the result more than earlier ones.

HbA1c does not show individual peaks, lows or episodes of hypoglycemia, and it does not reveal when fluctuations occurred. Two people with a similar HbA1c can therefore have very different glucose profiles.

The value is given as a percentage or in mmol/mol. These units apply to HbA1c. They are not the same as the glucose units mg/dl or mmol/l.

Certain health conditions can affect how reliably the HbA1c value reflects glucose exposure. These include blood loss or a transfusion. Some forms of anemia and hemoglobin variants are also among them. Kidney or liver disease and pregnancy can also play a role in the assessment. The effect of these factors depends on the individual case.

Three measurements, three different questions

Measurement What it shows What it does not show on its own
Blood glucose Glucose in the blood at the time of measurement The whole course of the day or longer-term patterns
Tissue glucose via CGM Trend and direction of change in the subcutaneous tissue The exact blood value at the same moment in every situation
HbA1c Glucose exposure over the past weeks Individual peaks, lows and short-term fluctuations

A value that the CGM calculates from the recorded glucose data and that resembles HbA1c is not an HbA1c value measured in a laboratory. It can differ from the laboratory value.

How to interpret discrepancies

Different values do not automatically mean that a measurement is wrong. Blood and tissue measurements capture glucose at different sites and under different conditions. The HbA1c value, on the other hand, summarizes glucose exposure over a longer period.

First compare when the values were taken and what period they represent. If there is a marked discrepancy between HbA1c and repeated blood or CGM values, a doctor should interpret the findings. Factors that matter include the measurement history, the conditions of the measurement and possible influences on red blood cells. The discrepancy alone does not prove any particular cause.

Separate criteria apply to diagnosis. For type 2 diabetes, the diagnostic HbA1c threshold is 6.5 percent, or 48 mmol/mol. Such a threshold is not automatically a personal treatment target. Doctors assess laboratory values in the context of the person’s overall health and arrange further measurements if needed.