For most non-pregnant adults, the usual targets for continuous glucose monitoring (CGM) still apply in 2026. A sensor measures the glucose in the tissue under the skin and shows how it changes over time. What matters more is that the targets fit the individual person. The narrower range of 70 to 140 mg/dl is under discussion and is not a new general standard in 2026.
Besides time in range, the frequency and duration of hypoglycemia matter. The right target also depends on age and on whether you are pregnant or have other health conditions. The burden of treatment also plays a role. The numbers serve as a basis for discussing your diabetes care, not as a prompt to change your therapy yourself.
The usual CGM targets remain
For many non-pregnant adults, the internationally accepted reference values still apply. TIR refers to the share of time in range, TBR to the time below the range, and TAR to the time above the range. The percentages refer to the total time measured.
| Metric | Reference value | What it means in everyday life |
|---|---|---|
| TIR: 70–180 mg/dl | over 70% | More than about 16 hours and 48 minutes a day in range |
| TBR: below 70 mg/dl | under 4% | Less than about 58 minutes a day below range |
| Time below 54 mg/dl | under 1% | Less than about 14 minutes a day in this particularly low range |
| TAR: above 180 mg/dl (10.0 mmol/l) | under 25% | Less than 6 hours a day above range |
| Time above 250 mg/dl | under 5% | Less than about 1 hour and 12 minutes a day |
| Glucose variability (CV) | no more than 36% | A measure of how much the values fluctuate |
These values are guidelines for many adults, not personal target values. A high TIR value alone does not show whether your glucose patterns are favorable. Frequent or severe hypoglycemia can occur even with plenty of time in range.
The HbA1c value shows your average glucose level over a longer period. However, it does not show when fluctuations or individual episodes of hypoglycemia occur. Studies show a link between a TIR of roughly 70 percent and an HbA1c of about 7 percent. However, an individual’s laboratory value cannot be reliably calculated from this. The GMI, an estimate based on sensor data, does not replace the laboratory HbA1c either.
Targets depend on your life situation
For older people with several health problems, a TIR target of at least 50 percent may be appropriate. For this group, the American Diabetes Association (ADA) also gives a 2026 guideline of limiting time below 70 mg/dl to less than 1 percent. This makes it possible to accept more time above the usual target range in order to avoid hypoglycemia. Age alone does not determine the target: health status, independence, risk of hypoglycemia and treatment burden all need to be weighed.
During pregnancy, a separate CGM range of 63 to 140 mg/dl applies. It cannot simply be compared with the usual range for non-pregnant adults. The appropriate percentage targets also differ depending on the type of diabetes and the pregnancy situation. Discuss your report with your care team; no blanket target for all pregnant women can be derived from it.
TiNG is not yet a general target
TiNG stands for “Time in Normal Glycemia”, meaning the time in the narrower range of 70 to 140 mg/dl. The Austrian guideline on diabetes technology mentions TiNG as a possible target value that is still being discussed. It does not use it to justify a general recommendation to replace the established range of 70 to 180 mg/dl for everyone.
A narrower range sounds more precise, but it is not automatically beneficial for everyone. So far, there is no evidence that a blanket switch to TiNG benefits everyone. If a report shows TiNG, ask whether the value is relevant to your personal situation and how to interpret it alongside TIR and hypoglycemia.
How to read your sensor report
For a meaningful analysis, about 14 days of sensor data are usually enough, provided the sensor was actively measuring at least 70 percent of the time. If a lot of data is missing, the report shows the actual pattern less accurately. When you prepare for an appointment, first check whether the measurement time is sufficient.
After that, hypoglycemia should be the focus, especially time below 54 mg/dl. Only then is it worth looking at high values, TIR and fluctuations. This way, a good TIR figure is not the only yardstick. Take the report with you to your appointment and ask which metric matters most for you and which changes would actually be feasible in your daily life.
When glucose changes quickly, sensors sometimes show values with a delay. If a reading does not match your symptoms or your expectations, follow the instructions in your device’s user manual and discuss the next steps with your care team. Do not change insulin doses or other treatments based on a single sensor reading or a general target value.
In the event of severe hypoglycemia, for example if a person is unconscious or cannot swallow safely, call your local emergency number. Do not give an unconscious person anything to eat or drink, and follow any emergency plan you have in place.
Sensors, pumps, and connected pens
CGM is not only relevant for people who use an insulin pump. Depending on individual needs, the ADA also recommends its use for people on insulin therapy or on certain treatments that can cause hypoglycemia. Studies in type 2 diabetes without insulin show somewhat better glucose metrics and higher satisfaction in some cases. However, the benefit is not the same in every group, so CGM is not an automatic solution for everyone.
Automated insulin delivery (AID) systems connect a glucose sensor to an insulin pump. They adjust insulin delivery based on sensor data, but they do not take over every decision. For 2026, the ADA recommends AID mainly for people with type 1 diabetes and for people with type 2 diabetes who inject insulin several times a day. AID is also an option for selected people with type 2 diabetes who use basal insulin and are not reaching their personal goals. The choice must fit the needs and abilities of the individual. You can read more in our article on AID in type 2 diabetes.
Connected insulin pens record when insulin was delivered and can combine this information with CGM traces in an app. This makes it easier to discuss patterns, but it replaces neither a medical assessment nor an individual treatment decision. Good training matters too: poorly set or overly frequent alarms can be a burden. Skin irritation, data access, and the availability of sensors are also part of the practical choice.
Checking access in Germany
Clinical recommendations and cost coverage are separate questions. The ADA guideline comes from the US, while the Austrian ÖDG guideline was written for Austria. Both provide clinical guidance, but they do not determine which devices are available in Germany or reimbursable in an individual case. For questions about care in Germany, the recommendations of the German Diabetes Society and the decisions of the Federal Joint Committee (Gemeinsamer Bundesausschuss) are important. A specific prescription or cost coverage must be clarified on an individual basis. The article on Diabetes Guidelines 2026 explains further changes to the recommendations.